LXSC-D3 Single Jet 80mm Length Water Meter
1. Small, light
2. Magnetic drive, lower transmission resistance
3. Magnetic shield, for external magnetic field protection
4. Sealed dry dial register ensures clear reading
5. Register can rotate more than 360° For easily reading in any position
6. Inlet strainer
Compliance with Standard
Technical data conforms to ISO 4064 Class B Standard for horizontal installation
Options
1. U. S. Gallon(USG) for selecting
2. Meter equipped with reed switch is available
Installation Requirements
1. The meter should be installed in horizontal position with the register face upwards
2. Pipeline must be flushed before installation
3. The meter should be constantly full of water during operation
Application
Measuring the volume of cold potable water passing through the pipeline
Working Conditions
1. Water temperature: ≤ 40°
2. Water pressure: ≤ 1.6Mpa
TYPE |
SIZE |
CLASS |
FLOW |
READING |
Qmax |
Qn |
Qt |
Qmin |
min |
max |
|
mm |
|
m3/h |
L/h |
m3 |
LXSC-13/15D3 |
13/15 |
A |
3 |
1.5 |
150 |
60 |
0.001 |
99999 |
B |
120 |
30 |
LXSC-20D3 |
20 |
A |
5 |
2.5 |
250 |
100 |
0.001 |
99999 |
B |
200 |
50 |
Maximum Permissible Error:
1. In the lower zone from Qmin inclusive up to but excluding Qt is ± 5%
2. In the upper zone from Qt inclusive up to and including Qmax is ± 2%
Arrow are indicated on the both sides of the meter body.
The lid can open not more than 120° .