Customization: | Available |
---|---|
Install: | Horizontal |
Medium Temperature: | Hot Water |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Dimensions and Weight |
|||||||
Nominal diameter | DN | 15 | 20 | 25 | 32 | 40 | 50 |
Body thread | D | G3//4B | G1B | G11/4B | G11/2B | G2B | G21/2B |
Connector thread | d | R1/2 | R3/4 | R1 | R11/4 | R11/2 | R2 |
Body length mm | L | 165 | 190 | 260/225 | 260/230 | 300/245 | 300/280 |
Overall length mm | L1 | 259 | 294 | 380/345 | 384/354 | 431/376 | 448/428 |
Width mm | W | 94 | 94 | 98 | 98 | 122 | 145 |
Meter height mm | H | 107.5 | 107.5 | 117.5 | 117.5 | 141.5 | 177 |
Weight without connectors Kg | 1.5 | 1.7 | 2.6/2.4 | 2.8/2.7 | 5.1/4.8 | 8.5/8.2 | |
Weight with connectors Kg | 1.68 | 1.98 | 3.12/2.92 | 3.6/3.5 | 6.14/5.84 | 10.22/9.92 | |
Nominal diameter | DN | 15 | 20 | ||||
Body length for selecting mm | L | 110 | 130 | 145 | 170 | 190 | 160 |
DN50 (Flanged ends):11.5kg. L1 is the total length when coupling gaskets without compression |
Main Technical Date | |||||||
Nominal diameter | DN | 13 | 20 | 25 | 32 | 40 | 50 |
Maximum flow rate m³/h | Qmax | 3.0 | 5.0 | 7.0 | 12 | 20.0 | 30.0 |
Nominal flow rate m³/h | Qn | 1.5 | 2.5 | 3.5 | 6.0 | 10.0 | 15.0 |
Transition flow rate l/h | Qt | 120 | 200 | 280 | 480 | 800 | 3000 |
Minimum flow rate l/h | Qmin | 30 | 50 | 70 | 120 | 200 | 450 |
Maximum reading m³ | 99999.99995 | 999999.99995/999999.9995 | |||||
Minimum reading m³ | 0.000 05 | 0.00005/0.0005 | |||||
Maximum Permissible Error: In the lower zone from Qmin inclusive up to but excluding Qt is ±5% In the upper zone from Qt inclusive up to and including Qmax is ±2% |