LXSC-D5 Single Jet Dry Type Vane Wheel Water Meter
Features
Small, light
Without retaining ring and lid
Nickel-plated body
Magnetic drive, lower transmission resistance
Sealed dry dial register ensures clear reading
Register can rotate more than 360° For easily reading in any position
Inlet strainer
Compliance with Standard
Technical data conforms to ISO 4064 Class B Standard for horizontal installation
Options
U. S. Gallon(USG) for selecting
Meter for hot water up to 40° Is available
Installation Requirements
The meter should be installed in horizontal position with the register face upwards
Pipeline must be flushed before installation
The meter should be constantly full of water during operation
Application
Measuring the volume of cold potable water passing through the pipeline
Working Conditions
Water temperature: ≤ 40C
Water pressure: ≤ 1.6MPa
Main Technical Data |
Nominal diameter |
DN |
13 |
20 |
Maximum flow rate m3/h |
Qmax |
3.0 |
5.0 |
Nominal flow rate m3/h |
Qn |
1.5 |
2.5 |
Transition flow rate l/h |
Qt |
120 |
200 |
Minimum flow rate l/h |
Qm |
30 |
50 |
Maximum reading m3 |
99999.99995 |
Minimum reading m3 |
0.00005 |
Maximum Permissible Error:
In the lower zone from Qmin inclusive up to but excluding Qt is ±5%
In the upper zone from Qt inclusive up to but excluding Qt is ±2% |