Dimensions and Weights | |||||
Nominal diameter | DN | 13 | 20 | 25 | 32 |
Body thread | D | G3/4B | G1B | G11/4B | G11/2B |
Connector thread | d | R1/2 | R3/4 | R1 | R11/4 |
Body length | L | 110/190 | 130 | 160 | 160 |
Overall length | L1 | 204/284 | 234 | 280 | 284 |
Width | W | 87 | 87 | 87 | 110 |
Meter height | H | 91 | 91 | 91 | 128.5 |
Weight without connectors KG | 0.8/0.95 | 0.97 | 1.2 | 2.25 | |
Weight with connectors KG | 0.98/1.13 | 1.25 | 1.72 | 3.05 | |
Attention: "L1" is the total length when coupling gaskets without compression |
Main Technical Date | |||||
Nominal diameter | DN | 13 | 20 | 25 | 32 |
Maximum flow rate m³/h | Qmax | 3.0 | 5.0 | 7.0 | 12.0 |
Nominal flow rate m³/h | Qn | 1.5 | 2.5 | 3.5 | 6.0 |
Transition flow rate l/h | Qt | 120 | 200 | 280 | 480 |
Minimum flow rate l/h | Qmin | 30 | 50 | 70 | 120 |
Maximum reading m³ | 99999.99995 | ||||
Minimum reading m³ | 0.00005 | ||||
Maximum Permissible Error: In the lower zone from Qmin inclusive up to but excluding Qt is ±5% In the upper zone from Qt inclusive up to and including Qmax is ±2% |