Customization: | Available |
---|---|
Install: | Horizontal |
Medium Temperature: | Cold Water |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Single Jet Dry Type Electronic Water Meter
Class B, R100
Model: LXSC-E5R
Small, light
Magnetic drive, lower transmission resistance
Magnetic shield, for external magnetic field protection
Sealed dry dial register ensures clear reading
Register can rotate more than 360° For easily reading in any position
Inlet strainer
Ultra-low power consumption and long life design
LCD digital direct reading accurately displays measurement information
Compliance with Standard
Technical data conforms to ISO 4064 Class B Standard for horizontal installation
Installation Requirements
1. The meter should be installed in horizontal position with the register face upwards
2. Pipeline must be flushed before installation
3. The meter should be constantly full of water during operation
Application
Measuring the volume of cold potable water passing through the pipeline
Working Conditions
1. Water temperature: ≤ 40°
2. Water pressure: ≤ 1.6Mpa
Maximum Permissible Error:
1. In the lower zone from Q1 inclusive up to but excluding Q2 is ± 5%
2. In the upper zone from Q2 inclusive up to and including Q4 is ± 2%