Customization: | Available |
---|---|
Accuracy: | ≤±0.1% |
Main Application: | Water |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item |
Specification |
Diameter |
DN15,DN25,DN50,DN80,DN100,DN150 (Please contact us for other dimension) |
Range of flow |
Liquid:2.5~100000l/h Gas:0.07~3000m3/h |
Measure ratio |
10:1, 20:1(special) |
Accuracy |
0.5, 1.0, 2.5 (special) |
Pressure rating |
DN15,DN25,DN50: 4.0MPa(Max: 20MPa) DN80,DN100,DN150:1.6MPa (DN80:Max 10MPa;DN100:Max 6.4MPa:DN150:Max 4.0MPa) |
Medium temperature |
Standard:-30ºC~+120ºC,high temperature:120ºC~350ºC |
Power supply |
24VDC(12~36VDC) |
Output signal |
4~20mADC (two-wire configuration); attached HART Protocol allowed |
Output load |
500Ω(24V power supply) |
Environment temperature |
-25ºC~55ºC
|
Storage requirement |
Temperature:-40ºC~100ºC humidity:≤85% |
Connection mode |
Flange connecting. Flange standard: GB/T9119-2000; User's appointment allowed |
Cable interface |
M20×1.5 |
Housing ingress protection |
IP65 |
Explosion-proof |
Intrinsic safety type:ExiaIICT6 explosion-proof type:ExdIICT6 |
Pressure loss |
See table of flow for detailed information |
Viscosity of medium |
DN15:η<5mPa.s DN25:η<250mPa.s DN50~DN150:η<300mPa.s |
Material |
R1:304,1Cr18Ni9Ti; Ro:316,0Cr18Ni12Mo2Ti; RL:316L,00Cr17Ni14Mo2Ti; Ti:Titanium alloy; Rp:PTFE lining |