• LXLC WPH Removable Element Woltman Dry Dial Cold (Hot) Dn 80~200 Water Meter
  • LXLC WPH Removable Element Woltman Dry Dial Cold (Hot) Dn 80~200 Water Meter

LXLC WPH Removable Element Woltman Dry Dial Cold (Hot) Dn 80~200 Water Meter

Install: Horizontal
Medium Temperature: Cold Water & Hot Water
Level Measurement: B
Counter Instructions: Mechanical
Nominal Diameter: Big Diameter
Application: Industrial
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
LXLC (80-200)E
Principle
Volumetric Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter

Product Description

LXLC Removable Element Woltman Cold (Hot) Water Meter 
This type of water meter can be used for a remote reading transmission system as equipped with a built-in sensor. 
 

Application

--Measuring the volume of cold (hot) water passing through the pipeline

Feature:

--Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;

--Dry-dial, Magnetic drive sensitive action, small pressure loss;

--Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;

--Selected high quality materials for steady & reliable characteristic;

--Technical data conform to international standard ISO 4064.

Working condition

Water temperature: 0.1C~40C ( 0.1C~90C for hot water meter)

Water pressure: ≤1Mpa (1.6MPa for special requirement)

LXLC removable element woltman water meter mechanism for cold (hot) water (optional : with pulse)
LXLC WPH Removable Element Woltman Dry Dial Cold (Hot) Dn 80~200 Water Meter
LXLC WPH Removable Element Woltman Dry Dial Cold (Hot) Dn 80~200 Water Meter

 

Maximum permissible errors
       in the lower zone from qmin inclusive up to but excluding qt is ±5%
       in the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter)

 
Type Size(mm) Class qsOverloadFlow qpPermanentFlow qtTransitional Flow qminMin.Flow Min. Reading Max. Reading
m3/h m3
LXLC-50 50 A 30 15 4.5 1.2 0.0002 999,999
B 3.0 0.45
LXLC-65 65 A 50 25 7.5 2.0 0.0002 999,999
B 5 0.75
LXLC-80 80 A 80 40 12 3.2 0.002 999,999
B 8.0 1.2
LXLC-100 100 A 120 60 18 4.8 0.002 999,999
B 12 1.8
LXLC-125 125 A 200 100 30 8 0.002 999,999
B 20 3
LXLC-150 150 A 300 150 45 12 0.002 999,999
B 30 4.5
LXLC-200 200 A 500 250 75 20 0.002 999,999
B 50 7.5
LXLC-250 250 A 800 400 120 32 0.002 999,999
B 80 12
LXLC-300 300 A 1200 600 180 48 0.02 9,999,999